rea
morluto
Reverse engineer anything with agents, from app behavior down to native binaries.
PROJECT TOPICS
PROJECT README
English | 中文
Other CAD MCP servers hand the agent tools. This one hands it a delivery it can prove.
A dsh / Codex plugin that lets an agent drive AutoCAD and SolidWorks for real: draw on an ISO sheet,
model a part, export STEP, and then read the result back and say whether it holds up. Two MCP servers,
two skills, and one command — dsh-sw-cad deliver — that turns "the agent says it finished" into a
verdict you can check. When the drawing has to be checked by someone else, a second profile also holds the
fits, material and surface finish to a table instead of trusting them.
dsh-sw-cad deliver D:\work\part-001 --require drawing,pdf
# verdict: pass (0 failure(s), 0 warning(s)) -> D:\work\part-001\delivery.json
| Part | What it is | Where it comes from |
|---|---|---|
autocad MCP server |
242 tools behind a search entry, COM or headless ezdxf | upstream U-C4N/Autocad-MCP, from PyPI, pinned |
solidworks MCP server |
66 tools behind a search entry, COM | upstream wzyn20051216/solidworks-automation-skill, cloned at install, pinned |
solidworks-automation skill |
66 Python modules: sw_*.py COM wrappers, OCCT/FEA/DFM, GB/T drawing sub-skill |
same upstream |
autocad-mcp-pro skill |
How to drive the AutoCAD MCP: layer discipline, ISO 7200 title block, real dimension entities, the delivery gate | authored here — upstream ships no AutoCAD skill |
dsh-sw-cad CLI |
install, doctor, where, serve, deliver, mode | authored here |
lib/standards.json |
The value table half-delivery mode judges against: fits, material grades, heat and surface treatment, the Ra series | authored here |
patches/ |
Two upstream defects fixed, offered upstream as PRs | authored here |
Nothing upstream is vendored. The installer fetches the PyPI package and clones the skill at a pinned commit, so upstream keeps ownership of its code and you get its current release.
Three routes. Pick one.
1. As a dsh plugin — the whole install is one line; package.json declares dsh.bundle.patch, so dsh
loads cordis.patch.yml, which inserts one row: this package. On first load the plugin resolves its paths,
installs the pinned upstream servers if they are missing, then registers both MCP clients with absolute
paths. If that cannot succeed it throws with the failing path instead of registering rows that fail silently.
dsh plugin --profile web add dsh-sw-cad
2. npm, global — same result, plus the CLI on PATH:
npm install -g dsh-sw-cad
dsh-sw-cad install
dsh-sw-cad doctor
3. From a checkout — no npm needed, and the only route that gives you bootstrap.ps1 -Check, which
inspects ten things and repairs only what is missing:
git clone https://github.com/27painter/dsh-sw-cad.git
cd dsh-sw-cad
.\bootstrap.ps1 -Check # report only, changes nothing, exits 1 if something is missing
.\bootstrap.ps1 # install whatever is missing
[!WARNING] Route 3 also writes
~/.dsh/cordis.patch.yml. With the plugin installed that is a second registration of the same two servers under the sameserverName, and dsh refuses the duplicate — the session fails to start. Use one route or the other; with the plugin, keep that file at[].
Prerequisites: Windows 10/11 with AutoCAD and/or SolidWorks, Python ≥ 3.11, and dsh or Codex. Node ≥ 20 for routes 1 and 2. Git optional — the installer falls back to a codeload zip when git is blocked.
The two upstream projects' own install instructions, kept verbatim for debugging a hand install, are in
docs/upstream-install.md.
A machine with only one CAD registers only that server. The plugin checks the COM registry before
registering anything (lib/probe.py; it does not launch either application), so a machine with neither
registers nothing and says so, rather than offering tools that could only fail. SW_CAD_DISABLE=autocad
turns that decision into a setting.
[!IMPORTANT] Start AutoCAD / SolidWorks first, as the same user. COM crosses a process boundary that Windows guards by user and integrity level. An agent started elevated while the CAD app runs normally (or the reverse) connects to nothing, and it looks like "the tool did nothing".
This rule is specific to COM.
dsh-nxdrives NX through NXOpen inside the NX process, so an open NX window cannot be attached to and that plugin starts its own batch session instead. Do not carry the habit across.
Describe the drawing; the skill loads itself.
Open AutoCAD, draw a bearing housing: base 120×80×10, upright 60 high × 12 thick,
φ40 through hole on top. ISO A3 sheet with title block and dimensions, save to
D:\AutoCad and export PDF.
In SolidWorks, build a flange: OD 100, 20 thick, 30 bore, four M10 bolt holes on a
bolt circle. Save as SLDPRT and export STEP.
Four things learned the hard way:
params:
call_tool(name="solidworks_sketch_and_extrude", arguments={"params": {"shape": "rectangle", ...}})
AutoCAD tools take theirs flat. The pydantic complaint about a missing params field is the hint.This is the part that is not in the upstream projects.
The two skills end differently. The AutoCAD side calls drawing_finalize — an eight-step validator that
raises instead of returning, so a model cannot claim success over a broken drawing. The SolidWorks side
asks for four previews and a review report, and trusts the model to look at them. deliver is the shared
ending: it starts no CAD, reads what landed on disk, and exits non-zero when it does not hold up.
dsh-sw-cad deliver D:\work\part-001 --require drawing,pdf
dsh-sw-cad deliver D:\work\part-001 --out D:\work\delivery.json --json
| kind | what is actually read |
|---|---|
.dxf |
ezdxf: DIMENSION entities, layer table, $INSUNITS, whether a paper-space layout has anything on it, the plot sheet against ISO 216, whether 比例/SCALE is stated, line-weight levels, the font behind Chinese text, dimension texts that sit on top of each other, a title-block hint |
.dwg |
header only — the AC1032-style version tag; counting entities needs a converter |
.pdf |
PyMuPDF: page size against ISO 216, and whether the text layer is real |
.step |
FILE_SCHEMA resolved to AP203/214/242, entity and CARTESIAN_POINT counts, bounding box from the raw points — which catches a scaled part or an export with no geometry. AP203 warns: it drops colour and assembly structure |
.sldprt / .sldasm |
presence, size, file signature. Geometry is not checked — that needs the application |
*_review_report.json |
evaluation.status == pass, and no issues |
A failed run reads like this, which is the point:
drawing empty.dxf 18470 B
FAIL drawing.dimensions 0 DIMENSION entities in modelspace
FAIL drawing.units $INSUNITS=0 (unitless)
FAIL drawing.sheets no sheet has anything on it; nothing frames the drawing
step old.step 1779 B
warn step.pmi AP203 drops colour and assembly structure; use AP214 or AP242
FAIL step.entities 40 entities, 40 CARTESIAN_POINTs
report part_review_report.json 101 B
FAIL review.status evaluation.status='fail'
verdict: fail (5 failure(s), 1 warning(s))
Exit 0 means the delivery holds up, 1 means it does not. An empty folder is a failure — a job that
produced nothing must never report success. Every file gets a SHA-256 in delivery.json, so "this is the
version that was checked" is a fact rather than a filename.
Warnings never change the exit code and always carry their reason: AP203, an unreadable DWG, a native part that was not opened, a missing Python dependency, a drawing with only one line weight.
What it does not check, and will not pretend to: tolerance and fit values (H7/g6), material, heat
treatment, surface finish, whether a dimension chain closes, whether the part can actually be machined.
The tools let a model type any of those, and there is no standard table here to compare against. pass
means the files hold up as files — not that the drawing is ready for the shop.
Rules per check, and the JSON shape: docs/delivery.md. The AutoCAD skill ships the
step as item 6 of its workflow; the SolidWorks skill is upstream text and is not modified here, so on that
route the check has to be invoked — in the task instruction, or as the last step of your script.
normal (default) checks the files. half also requires the values written on the drawing to come from
lib/standards.json: fits (H7/g6), material grades (45, 40Cr, 6061), roughness in the preferred
series. A value outside the table fails, and so does a drawing with no material and no Ra.
dsh-sw-cad mode half # set once; every later deliver inherits it
dsh-sw-cad mode # what is set now
dsh-sw-cad deliver D:\work\part-001 --profile half # one-off override
The choice is made once per job, not per part — a batch of twenty drawings should not stop and ask twenty times. The skill asks a single question at the start, and only when the request does not already say what the drawing is for.
delivery.json records "profile": "half" together with what is still unchecked. A half-delivery pass
is not full compliance, and the report says so instead of letting the two be confused.
Tool schemas are paid for before the first request. Both servers hide their catalogs behind their own discovery mode, so the client carries two entry tools per server instead of the whole catalog:
| Server | Entry tools | Idle cost | Catalog behind it |
|---|---|---|---|
autocad |
2 (search_tools, call_tool) |
365 tokens | 242 tools, searched by keyword |
solidworks |
3 (sw_search_tools, sw_describe_tool, sw_call_tool) |
474 tokens | 66 tools (50 solidworks_*, 14 cadstudio_*, 2 design_*) |
Connected directly the two servers cost 107,143 tokens before the first request; through this kit, 839 —
a 99.2% cut. Both sides measured the same way: tools/list bytes on the wire, counted with cl100k_base.
you speak natural language
│
├─ dsh / Codex loads a skill by its SKILL.md description
│ ├─ solidworks-automation → sw_*.py → COM → SolidWorks
│ └─ autocad-mcp-pro → search_tools / call_tool → MCP → AutoCAD
│
└─ MCP servers (cordis.patch.yml / codex config.toml)
├─ autocad upstream discovery, 2 entry tools
└─ solidworks upstream discovery, 3 entry tools
| CAD | Verified | Expected | Why |
|---|---|---|---|
| AutoCAD | 2026 — every COM path, live run; 2027 API-compatible | 2025 / 2024 / 2023 | COM goes through the long-stable ActiveX API. Upstream ships scripts\smoke_*_com.py to confirm a build, and the ezdxf backend needs no AutoCAD at all. |
| SolidWorks | 2026 SP4.1 (upstream's acceptance target), 2025 SP05 live run: part → sketch → rectangle → extrude → one body → save → STEP | 2024 / 2023 | The code carries explicit SW2024 fixes (Chinese edition: selecting a sketch by name, AddComponent4 returning None). The 2025 run produced a Chinese sketch name (草图1), so that path was exercised. 2023 has not been. |
Nothing refuses an older release — nothing checks a version number. They are simply outside what has been run, so start with one small job and look at the result.
What this package itself has run, live: system_status returns connected: true, backend: com, the
running version and active document; drawing_info returns entity count, extents and units; layer_list
returns the live layer table; the SolidWorks side reports status: ok with the instance detected. Both
serve targets answer a JSON-RPC handshake through this package's own entry point — AutoCAD reports
AutoCAD MCP Pro 3.4.11 with 2 entry tools, SolidWorks reports solidworks_mcp 1.30.0 with 3 — and
sw_call_tool with the Chinese query "健康检查" reaches solidworks_health_check against a live
SolidWorks 2026. dsh --dump-config loads both rows from this package.
| Symptom | What it usually is |
|---|---|
| Tools do nothing, no error | CAD not running, or running as a different user / integrity level than the agent |
| AutoCAD tools hang, then mention a modal dialog | A dialog is open in AutoCAD — a licence prompt, a save prompt, a recovery pane |
dsh fails to start after installing two ways |
Both a plugin row and a ~/.dsh/cordis.patch.yml entry. Keep one |
dsh --dump-config shows no rows |
The bundle patch was not picked up: check package.json declares dsh.bundle.patch |
| Codex lists no skills | Junctions under ~/.codex/skills\; Codex must support skills |
| AutoCAD screenshot is blank | The window is hidden or minimised. Geometry is still verifiable through the API |
sw_call_tool rejects a name |
It only accepts names from the catalog; run sw_search_tools first |
sw_search_tools returns nothing useful |
The server is in full mode, so there is no search entry — check SW_MCP_DISCOVERY |
| A dimension measures 0.0, or an edge length is null | The upstream patches are not applied: python patches\apply_patches.py --check |
deliver fails on a drawing you believe is fine |
Read the failing check id — each one names what it looked for and what it found |
dsh-sw-cad doctor # read-only, exit 1 when something is missing
dsh-sw-cad where # every path the servers will use
dsh --profile headless --dump-config # dsh sees both rows
python patches\apply_patches.py --check # read-only, exit 1 when a patch drifted
node bin\dsh-sw-cad.mjs serve solidworks # JSON-RPC handshake, expects 3 entry tools
node bin\dsh-sw-cad.mjs serve autocad # expects 2 entry tools
npm test # plugin wiring + 6 delivery-check cases
codex mcp list # Codex side
| Part | Origin | License |
|---|---|---|
| AutoCAD MCP server | U-C4N/Autocad-MCP, from PyPI, pinned to 1.6.0 | MIT |
| SolidWorks skill + MCP server | wzyn20051216/solidworks-automation-skill, cloned at a pinned commit | MIT |
AutoCAD skill, CLI, installer, deliver, patches/, this README |
this repository | MIT |
One deliberate exception to "we do not touch upstream": patches/ carries two fixes for upstream
defects that fail silently — a vertical linear dimension measures 0.0, and every edge's diameter and length
come back null. Both are open as pull requests upstream; until they land, install.ps1 applies them to the
installed copies and apply_patches.py --check reports drift. See patches/README.md
and THIRD-PARTY-NOTICES.md.
MIT, Copyright (c) 2026 27painter — see LICENSE. Upstream components keep their own MIT licences; this repository redistributes neither.
Listed on the M8ven Trust Index and on awesome-dsh-plugin.
CLASSIFICATION EVIDENCE
系统优先读取 GitHub Topics,再与站内分类词典和词根规则比对。当前命中: mcp、deepseek-harness。